Beskrivelse
Stepper Motor Driver Digital Display 42 57 Step Motor Drive Controller 5V‑24V DM542L
Item Type: Stepper Motor Driver
Parameter: DM542L
Minimum Continuous Output Current: 1A
Maximum Continuous Output Current: 4.2A
Minimum Logic Input Current: 7mA
Typical Logic Input Current: 10mA
Maximum Logic Input Current: 20mA
Maximum Power of The Whole Machine: 100W
Pulse Frequency: 0-200kHz
Minimum Insulation Resistance: 500MΩ
Maximum Logic Current of Digital Output Port: 100mA
Cooling Mode: Natural cooling or external radiator.
Usage: Avoid dust, oil mist and corrosive gas.
Temperature: 0℃ - 50℃
Ambient Humidity: 40-90% RH
Operating Environment Vibration: 10~55Hz/0.15mm
Storage Temperature: -20℃- +65 ℃
Interface definition:
Terminal 1 Symbol: A+
Terminal 1 Name: A Phase Motor Winding+
Terminal 1 Wire Color Description:
Terminal 2 Symbol: A-
Terminal 2 Name: A Phase Motor Winding-
Terminal 2 Wire Color Description:
Terminal 3 Symbol: B+
Terminal 3 Name: B Phase Motor Winding+
Terminal 3 Wire Color Description:
Terminal 4 Symbol: B-
Terminal 4 Name: B Phase Motor Winding-
Terminal 4 Wire Color Description:
Terminal 5 Symbol: VCC
Terminal 5 Wire Color Description: 18-48V DC
Terminal 6 Symbol: GND
Terminal 6 Wire Color Description: 18-48V DC
Control Signal Terminal:
Terminal 1 Symbol: DIR-
Terminal 1 Name: Direction Negative Input
Terminal 1 Description: Signal source +5V~24V universal, no need to connect resistance in series.
Terminal 2 Symbol: DIR+
Terminal 2 Name: Direction Positive Input
Terminal 2 Description: Signal source +5V~24V universal, no need to connect resistance in series.
Terminal 3 Symbol: PUL-
Terminal 3 Name: Pulse Negative Input
Terminal 3 Description: Signal source +5V~24V universal, no need to connect resistance in series.
Terminal 4 Symbol: PUL+
Terminal 4 Name: Pulse Positive Input
Terminal 4 Description: Signal source +5V~24V universal, no need to connect resistance in series.
Terminal 5 Symbol: ENA-
Terminal 5 Name: Motor Enable Negative Input
Terminal 5 Description: When the signal is valid, the motor is in free state and does not stall.
Terminal 6 Symbol: ENA+
Terminal 6 Name: Motor Enable Positive Input
Terminal 6 Description: When the signal is valid, the motor is in free state and does not stall.
Terminal 7 Symbol: ALM-
Terminal 7 Name: Alarm Signal Negative Output
Terminal 8 Symbol: ALM+
Terminal 8 Name: Alarm Signal Positive Output
Fault Description:
Fault Coding 1: Er01
Fault Description 1: Motor Overcurrent
Solution 1: Return to factory for inspection.
Fault Coding 2: Er02
Fault Description 2: Drive Overvoltage
Solution 2: Detect whether the motor is short-circuited or reduce the current.
Fault Coding 3: Er03
Fault Description 3: Hardware Fault
Parameter Monitoring Description:
Function Coding 1: L-00
Function Description 1: Speed
Function Coding 2: L-01
Function Description 2: Pulse Speed
Function Coding 3: L-02
Function Description 3: Given Pulse Number
Function Coding 4: L-03
Function Description 4: Useless
Function Coding 5: L-05
Function Description 5: Driver Fault Coding
Function Introduction 5: Check the number of received pulses in real time to determine whether the motor is out of step.
Description of Common Function Coding:
Function Coding 1 Parameter Setting: Number of subdivided pulses.
Function Coding 1: P-02
Function Description 1: 200-51200 arbitrary setting, 2000 in default.
Function Coding 2 Parameter Setting: Open loop current percentage.
Function Coding 2: P-10
Function Description 2: 50%, 8A x 50%=4A
Function Coding 3 Parameter Setting: JOG operation.
Function Coding 3: JOG
Function Description 3: Enter JOG and press ▲▼ to jog.
Function Coding 4 Parameter Setting: Motor direction.
Function Coding 4: P-18
Function Description 4: 0 reverse, 1 forward.
Function Coding 5 Parameter Setting: Restore to default.
Function Coding 5: S-20
Function Description 5: Set to 1 to restore default settings.
Main Function Parameters of Zone P:
P-00: Current loop proportional gain P, 1~327671500
P-01: Current loop integral gain I, 2~32766200
P-02: Subdivision setting, 200~512002000
P-09: Percentage of holding current, 0~100, 40
P-10: Percentage of open-loop current, 0~100, 50
P-15: Pulse filter enable, 0~6, 0. 0: not enabled, 1: enabled.
P-16: Filtering time, 0~25600500Us
P-18: Motor running direction, 0~1, 1. 0: positive direction, 1: negative direction.
P-19: Internal pulse acceleration, 0-5000200.
P-20: Maximum speed, 0-3000100.
P-21: Stroke turns, 0-65535, 0.
P-22: Stroke pulse, 0-65535200
P-23: Reciprocating times, 0-200, 1.
P-24: Direction, 0-1, 1.
P-25: Interval, 0-3000000.
P-26: Reciprocating, 0-1, 1.
P-27: Whether the internal pulse is enabled, 0-1, 0. 0: pulse mode, 1: internal operation mode.
P-28: Internal pulse trigger operation, 0-1, 0. 1: Press the key to trigger operation. 2: External trigger operation, PUL+, PUL -. 3: External JOG, PUL+, PUL -, DIR+, DIR -.
P-29: Jog running speed, 0-300100.
Parameter Setting:
Current Ratio Function Coding: P-00
Current Ra
-
Fruugo-ID:
388560857-833465598
-
EAN:
4621310502471