Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

NOK 339,00
+ NOK 221,99 i frakt

Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

  • Merke: Unbranded
Solgt av:

Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

  • Merke: Unbranded

NOK 339,00

Spar NOK 210,00 (38%)

Veiledende pris

NOK 549,00
På lager
+ NOK 221,99 i frakt

14-dagers returpolicy

Solgt av:

NOK 339,00

Spar NOK 210,00 (38%)

Veiledende pris

NOK 549,00
På lager
+ NOK 221,99 i frakt

14-dagers returpolicy

Betalingsmåter:

Beskrivelse

Digital Timer Delay Relay Switch for DC 6V-30V with Data Save Function Controller

DC 12V DDC-431 Timer Delay Relay Switch Digital Data Save Delay Controller DC 6V-30V - Powerful function with one-button emergency stop (STOP button), reverse connection protection, no damage during reverse polarity, power-off memory - Features sleep mode: after 5 minutes of inactivity, display automatically turns off; wake by pressing any button - Supports independent settings for OP, CL, and LOP parameters; settings are saved automatically upon power down, meeting a wide range of application needs Product Manual: Working voltage: DC 6V–DC 30V (wide voltage with reverse polarity protection) Trigger signal source: High-level trigger DC 3.0V–24V; signal ground connected to system ground for improved anti-interference performance; can be shorted to ground Output capacity: DC 30V/10A or AC 250V/10A Product size: 64mm x 35mm x 19.3mm Mounting hole diameter: 3mm Operating temperature: -40°C to 85°C Operating Modes: P1 Mode: After signal trigger, relay turns on for OP time, then turns off. During OP time: P1.1: Signal triggered again P1.2: Signal re-triggers timing P1.3: Signal resets, relay disconnects, timing stops P2 Mode: Upon trigger signal, relay turns off for CL time, then turns on for OP time. After timing completes, relay turns off. P3.1: Trigger signal initiates relay on for OP time, off for CL time, then repeats cycle. Number of cycles (LOP) can be set. If signal is given again during cycle, relay disconnects and timing stops. P3.2: No trigger required after power-on. Relay turns on for OP time, off for CL time, and repeats cycle. Number of cycles (LOP) can be set. P4 Mode: Signal hold function. When trigger signal is present, timing resets and relay remains on. When signal is removed, relay turns off after OP timing. If signal reappears during timing, timing resets. Relay Enable Mode: ON: Relay can conduct during OP time OFF: Relay is disabled and remains off Short press STOP button on main interface to switch between ON and OFF. Current state flashes briefly before returning to main interface. This provides emergency stop functionality. Sleep Mode (long press STOP to view current mode): C-P Sleep Mode: Display turns off automatically after 5 minutes of inactivity; program continues running O-d Normal Mode: Display remains on continuously Press and hold STOP button for 2 seconds to toggle between C-P and O-d modes. Current mode flashes briefly before returning to main interface. Timing Range Selection: After setting parameter in mode selection interface, press STOP button to select timing range: XXX. Decimal point at units place: 1 second to 999 seconds XX.X Decimal point at tenths place: 0.1 seconds to 99.9 seconds X.X.X All decimal points illuminated: 1 minute to 999 minutes Example: To set OP to 3.2 seconds, set decimal point to tenths place; display shows 03.2 Parameters: OP – On time CL – Off time LOP – Cycle count (1–999); 0 indicates infinite loop Parameters are independent and shared across modes. For example, if OP is set to 5 seconds in P1.1, switching to P1.2 will retain OP = 5 seconds unless changed. Display 000 on main interface and press SET button to view OPL, LOP, and corresponding values In modes with only OP (e.g., P1.1, P1.2, P1.3), short press SET to display OP and time In modes with OP, CL, LOP (e.g., P3.1, P3.2), short press SET to display OP, CL, and LOP with respective values After mode setup, press SET on main interface to easily review current mode parameters Parameter Setting Procedure: 1) Determine desired relay operating mode 2) From main interface (module displays current mode on power-up, default P1.1), press and hold SET button for 2 seconds, then release to enter mode selection interface 3) Select desired mode for configuration
  • Fruugo-ID: 405214894-859612189
  • EAN: 8324364702694

Levering og retur

Sendes i løpet av 3 dager

  • STANDARD: NOK 221,99 - Levering mellom kl fre. 16 januar 2026–ons. 28 januar 2026

Sendes fra Kina.

Vi gjør vårt beste for å sikre at produktene du bestiller, leveres til deg i sin helhet og i samsvar med dine spesifikasjoner. Skulle du likevel motta en ufullstendig bestilling eller andre varer enn dem du bestilte, eller hvis du av en eller annen grunn ikke er fornøyd med bestillingen, kan du returnere bestillingen eller enkeltvarer i bestillingen og motta full refusjon for varene. Se fullstendige retningslinjer for retur

Produktoverholdelsesdetaljer

Vennligst se samsvarsinformasjonen som er spesifikk for dette produktet skissert nedenfor.

Følgende informasjon er gitt av den uavhengige tredjepartsforhandleren som selger dette produktet.

Produsent:
Følgende informasjon skisserer kontaktinformasjonen til produsenten av det aktuelle produktet som selges på Fruugo.

  • Jiang Yan
  • Guangzhou Ruicai E-commerce Co., Ltd.
  • Room D2709, 203, 2nd Floor, No. 4, Yuejia 2nd Street,Shimen Street, Baiyun District,Guangzhou City,Guangdong Province
  • Guangzhou
  • CN
  • 510420
  • lu61027yeyamei632@163.com
  • 13192975727

Ansvarlig person i EU:
Følgende informasjon skisserer kontaktinformasjonen til den ansvarlige personen i EU. Den ansvarlige personen er den utpekte økonomiske aktøren basert i EU, som er ansvarlig for samsvarsforpliktelsene knyttet til det relevante produktet som selges til EU.

  • Van Lavazza
  • Y & H S.R.L.
  • Via Gravina 21 MT matera,Trani,Puglia
  • Trani
  • Italy
  • 75100
  • itlyhsrl@gmail.com
  • 0039 3917722149