70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

NOK 449,00
+ NOK 91,99 i frakt

70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

  • Merke: Unbranded
Solgt av:

70%~100% Adult Finger Clip Spo2 Blood Oxygen Saturation Sensor Probe Fit for CSI Model

  • Merke: Unbranded
Pris: NOK 449,00
Solgt av:
NOK 449,00
+ NOK 91,99 i frakt

På lager

Vi godtar følgende betalingsmetoder

Beskrivelse

Item Type: Blood Oxygen Probe <br>Material: Plastic <br>Applicable for CSI models, others are not applicable <br>Specification: LED 660nm/905nm/940nm <br>Maximum Output Power: 15 mw <br>Suitable for Adults with a weight >40kg, clamped on the index finger or any finger. <br> <br>Spo2 Test Range: 70%~100% <br>Spo2 Test Accuracy: ±2% when 90%~100%, ±3% when 70%~89% <br>Pulse Rate Test Range: 30~245 bpm <br>Pulse Rate Test Accuracy: ±3 bpm <br>Main Structure: Consists of plug, cable and probe <br>Application: Used for pulse oximeters and multi-parameter monitors to continuously and non-invasively collect and transmit the pulse and oxygen saturation signals of patients (adults with a body weight >40kg); not suitable for weak perfusion and exercise conditions Monitoring, the probe is not suitable for long-term monitoring, it should be checked every 4 hours or measured with 2 fingers. <br> <br>Contraindications: Do not fix this product in a location where the patient has tissue damage; it is not suitable for patients and users who are allergic to PVC, TPU, TPE, ABS plastics. <br> <br>Warning: <br>A) Improper use will cause inaccurate measurement. <br>B) When the light is too strong, the measurement will be inaccurate. In some cases, a piece of opaque material should be used to shade the light around the sensor. <br>C) The blood oxygen saturation probe should be moved to a new location at least every 4 hours. Because local skin conditions will affect the ability of the skin to withstand the placement of the probe, it is necessary to change the position of the sensor frequently according to the conditions of some patients. If the integrity of the skin changes, the probe needs to be moved to another location. <br>D) Dye in the blood vessel will cause inaccurate measurement. <br>E) The performance of the probe is easily affected by activities, so it is not suitable for active patients. <br>F) Do not use straps to fix the probe or tie it to death, because venous pulsation will cause inaccurate saturation measurement. <br>G) Like other armarium, cables should be placed so as not to entangle or suffocate the patient. <br>H) Do not use during MRI scan. Because the conductor current will cause burns. Moreover, the blood oxygen saturation probe will affect the MRI image, and the MRI device will also affect the accuracy of the blood oxygen measurement. <br>I) Do not change or modify this product at will. Because this will affect its performance or accuracy. <br>J) Do not use radiation, steam or ethylene oxide for degassing. <br>K) Do not immerse the product in liquid for cleaning and degassing. <br>L) Mobile phones or mobile RF communication equipment will affect the operation of this sensor. <br> <br>How to Use: <br>1) Place your index finger on the sensor window of the pulse oximetry probe, and touch the stop button at the end of your finger. <br>2) If the nail is too long, it will affect the fingertip to touch the stop button. <br>3) Open the lower cover of the finger clamp of the sensor to apply even force to the entire length of the gasket. Check the location of the sensor. If the index finger is placed incorrectly or cannot be used, you can use other fingers or use other types of oxygen sensors. Do not use the pulse oximetry probe on children’s thumbs or toes, or on the entire hands and feet. <br>Note: When selecting the sensor placement site, priority should be given to the limb site without arterial catheter, blood pressure cuff and venous infusion tube. <br>4) When placing the sensor, route the cable along the back of the hand. <br>5) Connect the pulse oximetry probe to the oximeter and check whether the operating procedure complies with the steps described in the operating manual. <br>Note: If the sensor cannot accurately monitor the pulse beating, it means that its position is improper or its place
  • Merke: Unbranded
  • Kategori: Puls-oksimetre
  • Lengde: 5
  • Vekt: 0.1
  • Høyde: 5
  • Bredde: 5
  • Fruugo-ID: 379354635-818866684

Levering og retur

Sendes i løpet av 24 timer

  • STANDARD: NOK 91,99 - Levering mellom kl tor. 09 oktober 2025–tor. 16 oktober 2025

Sendes fra Kina.

Vi gjør vårt beste for å sikre at produktene du bestiller, leveres til deg i sin helhet og i samsvar med dine spesifikasjoner. Skulle du likevel motta en ufullstendig bestilling eller andre varer enn dem du bestilte, eller hvis du av en eller annen grunn ikke er fornøyd med bestillingen, kan du returnere bestillingen eller enkeltvarer i bestillingen og motta full refusjon for varene. Se fullstendige retningslinjer for retur

Produktoverholdelsesdetaljer

Vennligst se samsvarsinformasjonen som er spesifikk for dette produktet skissert nedenfor.

Følgende informasjon er gitt av den uavhengige tredjepartsforhandleren som selger dette produktet.

Produsent:
Følgende informasjon skisserer kontaktinformasjonen til produsenten av det aktuelle produktet som selges på Fruugo.

  • Shenzhenyuandedianziyuouxiangongsi
  • Shenzhenyuandedianziyuouxiangongsi
  • Room 1401-04 Yousuo Bldg 2000
  • Jiaxian Road Gangtou Community
  • Bantian Subdistrict
  • Shenzhen
  • China
  • 518500
  • szrhkj41@163.com
  • 15819859068

Ansvarlig person i EU:
Følgende informasjon skisserer kontaktinformasjonen til den ansvarlige personen i EU. Den ansvarlige personen er den utpekte økonomiske aktøren basert i EU, som er ansvarlig for samsvarsforpliktelsene knyttet til det relevante produktet som selges til EU.

  • Huang Pengliang
  • FORCHAIN GmbH
  • Vilbeler Landstra?e73 60388 Frankfurt am Main
  • Frankfurt am Main
  • Frankfurt am Main
  • DE
  • 60388
  • nnicolesusan093@gmail.com
  • 1638127736